MI Heating Cable MISS

MI Heating Cable MISS

Features

  • High mechanical strength
  • Explosion- and fire-safe
  • Temperature resistance up to +600 °C
  • Power supply voltage up to 600 V
  • Delivered as cable or prefabricated heating units
  • High chemical resistance

Product Datasheet

Application Areas

Nuclear Industry - Sodium loops

Metal Forming Industry - Melting of low melt alloys

Underfloor heating

Building Industry - Bitumen/asphalt heating

Tank/vessel Heating

MISS heating cable is designed for heating pipelines, tanks and process equipment in the

temperature range from -60 to +600 °C, including aggressive and explosive areas.

MISS cables can be used in oil refining, chemical, pharmaceutical, food and other industries.

If the thermal output of the electric heating system is correctly calculated, the cable can be used in a broad temperature range.

Shipped as cable or ready-made heating units. Heating unit consists of a heating cable, couplings, cold cable inserts, cable glands and flexible installation wires.

Due to the high thermal stability of the magnesium oxide insulation, the MISS cable can safely operate at ambient temperatures up to +600 °C.

MISS cable has excellent mechanical strength and high corrosion resistance, can operate in aggressive environments and hazardous areas.

MISS cable is fire-resistant and safe to operate.

  • High mechanical strength
  • Explosion- and fire-safe
  • Temperature resistance up to +600 °C
  • Power supply voltage up to 600 V
  • Delivered as cable or prefabricated heating units
  • High chemical resistance

Technical Data

Technical data

Operating voltage  Up to 600 V
Maximum thermal resistance 800 °C
Ex marking Ex 60079-30-1 IIC T1 to T6 Gb
Ex 60079-30-1 IIIC T450°C to T85°C Db
RESIST. at 20 ℃ 2.1-36100 Ω/m
Construction 1 or 2 conductors

Required cable could be chosen in the tables “Cable references” with a preliminary determination of selection parameters:

Max voltage – 300 V / 600 V

Number of conducting wires – 1 / 2

Please contact us to select and get a price offer for a ready for installation MI-heating unit

CABLE REFERENCES (SINGLE CONDUCTOR 600V)


CABLE REF DIAMETER  RESIST. at 20 ℃ NOMINAL LENGTH NOMINAL WEIGHT 
     16C2.1      6.8      0.0021      130      218.0
     16C3.4      5.9      0.0034      170      158.1
     16C5.3      5.3      0.0053      210      121.8
     16C8.5      4.7      0.0085      195       92.4
     16C13      4.3      0.013      240       74.3
     16C21      4.0      0.021      210       65.4
     16K40      5.8      0.04      170      154.9
     16K50      5.4      0.05      200      131.9
     16K60      5.2      0.06      210      119.9
      16K80      4.8      0.08      190       99.4
    16K100      4.7      0.1      195       91.9
    16K120      4.5      0.12      210       82.2
    16N160      6.5      0.16      140      193.9
    16N200      5.9      0.2      170      159.7
    16N250      5.3      0.25      210      128.9
    16N400      4.7      0.4      200       95.9
    16N500      4.5      0.5      215       86.0
    16N630      4.3      0.63      235       76.6
  16N1000      3.9      1.0      290       60.9
  16N1600      3.6      1.6      335       50.8
  16N2500      3.4      2.5      300       45.5
   16N2800      3.4      2.8      300      45.3
   16N3300      3.4      3.3      300      45.1
   16N4000      3.2      4.0      335      39.9
   16N5200      3.2      5.2      335      39.6
   16N6300      3.2      6.3      335      39.0
 16N10000      3.2      10      335      38.7


CABLE REFERENCES (DUAL CONDUCTOR 600V)

CABLE REF DIAMETER RESIST. at 20 ℃ NOMINAL LENGTH NOMINAL WEIGHT
    26C8.4      9.8      0.0084      60      400.3
    26C13.4      8.7      0.0134      75      308.6
    26C21      7.9      0.021      95      246.9
    26C34      7.3      0.034      110      208.1
    26C54      6.3      0.054      145      153.9
    26C85      5.6      0.085      185      120.8
    26C130      5.3      0.13      215      104.8
    26K180      7.9      0.18      95      255.9
    26K260      7.4      0.26      105      220.5
    26K360     6.8      0.36      130      180.8
    26K500      6.4      0.5      145      159.3
    26K650      5.9      0.65      165      131.3
    26K1000     5.7      1.0      175      124.4
    26K1300      6.2      1.3      150      147.3
    26K2000     5.8      2.0      170      125.9
    26K3300      5.4      3.3      205      109.1
   26N4600     5.8      4.6      170      130.3
   26N8000      5.4      8.0      205      111.5
   26N13000      5.0      13.0      140      95.0
   26N27000     4.8      27.0      150      87.1
   26N40000      4.6      40.0      160      79.7
   26N60000      4.4      60.0      175      72.8
   26N72000     4.2      72.0      190      66.3

CABLE REFERENCES (DUAL CONDUCTOR  300V)

CABLE REF DIAMETER RESIST. at 20 ℃ NOMINAL LENGTH NOMINAL WEIGHT
     23K210      5.4      0.21      200      118.5
     23K300      5.0      0.3      240      99.4
     23K400      4.8      0.4      250      90.2
     23K480      4.8      0.48      250      89.4
     23K650      4.6      0.65      200      82.9
   23K1000      4.1      1.0      210      64.8
   23K1300      3.8      1.3      240      55.4
   23K2000      5.0      2.0      235      97.2
   23K2400      4.8      2.4      250      89.3
   23K3000     4.6      3.0      200      80.5
   23N4600      4.8      4.6      250      89.6
   23N7500      4.6      7.5      200      80.0
 23N11200     4.4      11.2      180      74.0
 23N14000      4.2      14.0      200      67.4
 23N18000      3.8      18.0      240      55.1
 23N26000      3.6      26.0      270      49.2
 23N40000     3.4      40.0      300      43.8
 23N50000      3.4      50.0      300      43.7
 23N60000      3.4      60.0      300      43.6
 23N72000      3.4      72.0      300      43.6

Note: For the required voltage 600 V above application, please contact us.


TABLE 5 GLAND SIZE 

     Design A, D, E 
 Design B   
Max. voltage (V) Max. current (amps)  Gland size (English)  (Metric)  Max. current (amps) Gland size (English)     (Metric)
     600      15      E1      M1      20      E1      M1
     600      20      E1      M1      25      E1      M1
     600      30      E2      M2      40      E2      M2
     600      50      E2      M2      70      E2      M2
     600      70      E2      M2      100      E2      M2

Note1:E1 stands for 1/2〞NPT;E2 stands for 3/4〞NPT;M1 stands for gland diameter M20;M2 stands for gland diameter M25. Stands model shall be advised properly while design.

Note2: 2-meter-long cold lead is supplied with heating cable. For special requirement, please contact us.