Self-Regulating Heating Cable LTM

Self-Regulating Heating Cable LTM
−60°C
+85°C

Features

  • 10 or 15 W/m
  • Self-regulating, automatically adjusts power output in response to ambient temperature
  • Thermoplastic or Fluoropolymer overjacket
Product Datasheet

Application Areas

Freeze protection of pipelines and vessels

Approvals

Self-Regulating Heating Cable LTM

LTM is an industrial grade self-regulating heating cable that can be used for freeze protection of pipelines and vessels.

The power output adjusts automatically in response to the ambient temperature.

Because of its self-regulating characteristics it will not overheat even when the cable is overlapped. This guarantees maximum safety and reliability.

The installation of LTM heating cable is quick and simple and requires no special skills or tools. Because of its parallel construction the heating cable can be fitted on site to exact length without any complicated design calculations.

The LTM cable with Fluoropolymer overjacket is characterized by high resistance against high temperatures, chemicals and UV radiation.

Termination, splicing and power connection components are available in convenient kits. 


  • 10 or 15 W/m
  • Self-regulating, automatically adjusts power output in response to ambient temperature
  • Thermoplastic or Fluoropolymer overjacket
  • Easy to install
  • Can be cut to required length on site without any complicated design calculations
  • Will not overheat even when overlapped
  • Full range of accessories available
  • UV and high chemical resistant (Fluoropolymer)
Technical Data
Rated voltage  230 VAC
Maximum continuous operating temperature (trace heater energized)  65 °C
Maximum continuous exposure temperature (trace heater de-energized)  85 °C 
Ambient temperature range −60 ... +55 °C
Minimum installation temperature:
Thermoplastic overjacket
Fluoropolymer overjacket
−30 °C
−60 °C
Minimum bending radius 25 mm
Maximum screen resistance 18 Ohm/km
Maximum braiding resistance 10 Ohm/km
Conductor cross-section 0.56 mm2
Dimension:
Thermoplastic elastomer overjacket, aluminum foil
Fluoropolymer overjacket, braiding
8.30×5.50 mm
8.60×5.40 mm
Weight:
Thermoplastic elastomer overjacket, aluminum foil
Fluoropolymer overjacket, braiding
66 kg/km
98 kg/km

  1. 0.56 mm2 nickel-plated copper conductors
  2. Semi-conductive self-regulating matrix
  3. Matrix insulation
  4. Aluminum foil with drainage wires or tinned copper braid
  5. Overjacket Thermoplastic or Fluoropolymer